Published 1991
| Version v1
Book
Laser Doppler velocimeter applied to superflow measurement
Description
The application of a Laser Doppler velocimeter (LDV) to He II flow measurement was attempted for sufficiently high accuracy and resolution in both time and space. The detail of the application technique and some results measured with the LDV for the thermal counterflow jet are described here to demonstrate the applicability of an LDV as major diagnostic means for the He II flow facility. 5 refs
Additional details
Publishing Information
- Publisher
- Springer-Verlag.
- Imprint Place
- New York, NY (United States)
- Imprint Title
- High Reynolds number flows using liquid and gaseous helium
- Imprint Pagination
- 280 p.
- Journal Page Range
- p. 215-221.
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 24018030
- Subject category
- S75: CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY;
- Descriptors DEI
- ACCURACY; COUNTERFLOW SYSTEMS; CRYOSTATS; DIAGNOSTIC TECHNIQUES; FLUID MECHANICS; HELIUM II; LASER DOPPLER ANEMOMETERS; MEASURING METHODS; RESOLUTION; SUPERFLUIDITY; TEST FACILITIES
- Descriptors DEC
- ANEMOMETERS; CONTROL EQUIPMENT; EQUIPMENT; EVEN-EVEN NUCLEI; FLUIDS; HELIUM ISOTOPES; HELIUM 4; ISOTOPES; LIGHT NUCLEI; MEASURING INSTRUMENTS; MECHANICS; NUCLEI; QUANTUM FLUIDS; STABLE ISOTOPES; THERMOSTATS