Published April 1992 | Version v1
Report Restricted

Post-test analysis of LOBI test BT-12 using RELAP5/MOD2

  • 1. UKAEA Atomic Energy Establishment, Winfrith (United Kingdom)

Description

This report describes calculations carried out with RELAP5/MOD2 on LOBI experiment BT-12, a large steam line break. The following sensitivity studies were performed: heat losses on the intact steam generator; discharge coefficient at break; water in steam lines; nearly implicit numerics. Qualitatively the general trends of BT-12 were predicted well, in particular the timing of events was fairly accurate

Availability note (English)

MF available from INIS under the Report Number; OSTI as TI92014120; NTIS; INIS; GPO.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
63 p.
Report number
NUREG/IA--0079

Optional Information