Published 1987 | Version v1
Book

Beam diagnostics and control for SLC

Creators

  • 1. Stanford Linear Accelerator Center, Stanford Univ., Stanford, CA 94305 (USA)

Description

Construction of the SLAC Linear Collider has posed some new problems in beam diagnostic device design. Typical beam sizes are small when compared with conventional storage rings, orbit tolerances are tighter and the pulsed nature of the machine means that signal to noise enhancement by averaging is not always possible. Thus the diagnostics must have high resolution, high absolute accuracy and must deliver data from a single puls. In practice the required performance level depends on the function and dynamics of a given region in the collider. In this paper, the authors review the major beam diagnostic system and then discuss the global data acquisition schemes. Because space is limited each system is described only in a very cursory fashion. More details may be found in the cited papers

Additional details

Publishing Information

Publisher
IEEE Service Center.
Imprint Place
Piscataway, NJ (USA)
Imprint Title
Proceedings of the 1987 IEEE particle accelerator conference: Accelerator engineering and technology
Journal Page Range
p. 508-511.

Conference

Title
Particle accelerator conference.
Dates
16-19 Mar 1987.
Place
Washington, DC (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
19078298
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CONTROL SYSTEMS; DIAGNOSTIC TECHNIQUES; LUMINOSITY; PARTICLE BEAMS; PHASE SPACE; RESOLUTION; REVIEWS; SIGNAL-TO-NOISE RATIO; SPECIFICATIONS; STANFORD LINEAR COLLIDER
Descriptors DEC
ACCELERATORS; BEAMS; DOCUMENT TYPES; LINEAR ACCELERATORS; MATHEMATICAL SPACE; OPTICAL PROPERTIES; PHYSICAL PROPERTIES; SPACE