Published October 2019 | Version v1
Journal article

Measurement of kinetic parameter of the Jordan research and training reactor

  • 1. Korea Atomic Energy Research Institute, Daedeok-daero 989-111, Yuseong-gu, Daejeon (Korea, Republic of)
  • 2. Jordan Research and Training Reactor, Jordan Atomic Energy Commission, Irbid (Jordan)

Description

Highlights: • The βeff/Λ was measured during the commissioning of JRTR in 2016. • The noise techniques of correlation, PSD, and VTMR were applied. • The difference between the measured and calculated βeff/Λ was within 13%. - Abstract: The kinetic parameter of the Jordan Research and Training Reactor (JRTR) was measured during commissioning. Neutron noise analysis techniques of correlation, power spectral density (PSD), and variance to mean ratio (VTMR) were applied to determine the prompt neutron decay constant (α) at several zero-power subcritical states. The ratio of the effective delayed neutron fraction to prompt neutron reproduction time (βeff/Λ) corresponding to α at a critical state was estimated by a linear extrapolation of α values as a function of inverse count rate. The βeff/Λ value determined by using the time series neutron data from the BF3 detectors was 54.76–60.32 s-1 and was compared to the calculated one of 61.70 s-1 by the McCARD code with the ENDF/B-VII.0 nuclear library. The relative difference between the measurement and the calculation was within 13%, regardless of the noise analysis techniques.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.anucene.2019.04.047

Additional details

Identifiers

DOI
10.1016/j.anucene.2019.04.047;
PII
S0306454919302312;

Publishing Information

Journal Title
Annals of Nuclear Energy (Oxford)
Journal Volume
132
Journal Page Range
p. 322-326
ISSN
0306-4549
CODEN
ANENDJ

Optional Information

Notes
© 2019 Elsevier Ltd. All rights reserved.