Diagnostic reference levels and complexity indices in interventional radiology: a national programme
Creators
- Ruiz-Cruces, R.1
- Perez-Martinez, M.1
- Pastor-Vega, J.M.1
- Canete, S.1
- Vano, E.2
- Fernandez-Soto, J.M.2
- Sanchez-Casanueva, R.2
- Gallego-Beuter, J.J.2
- Carrera-Magarino, F.3
- Moreno-Rodriguez, F.3
- Moreno-Sanchez, T.3
- Soler-Cantos, M.M.4
- Canis-Lopez, M.4
- Hernandez-Armas, J.5
- Diaz-Romero, F.J.5
- Rosales-Espizua, F.6
- Lopez-Medina, A.6
- Gonzalez-de-Garay, M.6
- Martin-Palanca, A.7
- Gil-Agudo, A.8
- Zarca-Diaz, M.A.8
- Zapata-Jimenez, J.C.8
- Parra-Osorio, V.9
- Munoz Ruiz-Canela, J.J.9
- Moreno-Saiz, C.9
- Galan-Montenegro, P.9
- 1. University of Malaga, School of Medicine, Malaga (Spain)
- 2. Complutense University, San Carlos Hospital, Medical School, Madrid (Spain)
- 3. Juan Ramon Jimenez University Hospital, Huelva (Spain)
- 4. Reina Sofia University Hospital, Cordoba (Spain)
- 5. University Hospital of Canary Islands, Tenerife (Spain)
- 6. Basurto Hospital, Bilbao (Spain)
- 7. Virgen de la Victoria University Hospital, Malaga (Spain)
- 8. General University Hospital, Ciudad Real (Spain)
- 9. Carlos Haya University Hospital, Malaga (Spain)
Description
To propose national diagnostic reference levels (DRLs) for interventional radiology and to evaluate the impact of the procedural complexity on patient doses. Eight interventional radiology units from Spanish hospitals were involved in this project. The participants agreed to undergo common quality control procedures for X-ray systems. Kerma area product (KAP) was collected from a sample of 1,649 procedures. A consensus document established the criteria to evaluate the complexity of seven types of procedures. DRLs were set as the 3rd quartile of KAP values. The KAP (3rd quartile) in Gy cm2 for the procedures included in the survey were: lower extremity arteriography (n = 784) 78; renal arteriography (n = 37) 107; transjugular hepatic biopsies (THB) (n = 30) 45; biliary drainage (BD) (n = 314) 30; uterine fibroid embolization (UFE) (n = 56) 214; colon endoprostheses (CE) (n = 31) 169; hepatic chemoembolization (HC) (n = 269) 303; femoropopliteal revascularization (FR) (n = 62) 119; and iliac stent (n = 66) 170. The complexity involved the increases in the following KAP factors from simple to complex procedures: THB x4; BD x13; UFE x3; CE x3; HC x5; FR x5 and IS x4. The evaluation of the procedure complexity in patient doses will allow the proper use of DRLs for the optimization of interventional radiology. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-016-4334-2Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 26
- Journal Issue
- 12
- Journal Page Range
- p. 4268-4276
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 48000133
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BILIARY TRACT; BIOPSY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC USES; KERMA; KIDNEYS; LARGE INTESTINE; LEGS; LIVER; OPTIMIZATION; RADIATION DOSES; RADIOEMBOLIZATION; RADIOTHERAPY; SURGERY; UROGENITAL SYSTEM DISEASES; X RADIATION
- Descriptors DEC
- BODY; BRACHYTHERAPY; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; DISEASES; DOSES; ELECTROMAGNETIC RADIATION; GASTROINTESTINAL TRACT; GLANDS; INTESTINES; IONIZING RADIATIONS; LIMBS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIATIONS; RADIOLOGY; RADIOTHERAPY; THERAPY; USES