Tolerable parameter scatter of ultrasonic equipment for a 2 dB reproducibility of indications
Creators
- 1. Rheinisch-Westfaelischer Technischer Ueberwachungs-Verein E.V., Essen (Germany, F.R.)
Description
The ultrasonic equipment currently in use covers about 6 dB or more scatter of indications. In a broad research program the scatter for each of more than 30 parameters was investigated. From the results it can be concluded how small the parameter scatter has to be for the ultrasonic equipment to cause only a 2 dB scatter of indications in the future
Additional details
Publishing Information
- Publisher
- COFREND.
- Imprint Place
- Paris (France)
- Imprint Title
- Proceedings of the 7. International conference on non destructive evaluation in nuclear industry
- Imprint Pagination
- 466 p.
- Journal Page Range
- p. 105-108.
Conference
- Title
- 7. International conference on non destructive evaluation in nuclear industry.
- Dates
- 28 Jan - 1 Feb 1985.
- Place
- Grenoble (France).
INIS
- Country of Publication
- France
- Country of Input or Organization
- France
- INIS RN
- 18028348
- Subject category
- S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- MEASURING INSTRUMENTS; RELIABILITY; ULTRASONIC TESTING
- Descriptors DEC
- ACOUSTIC TESTING; MATERIALS TESTING; NONDESTRUCTIVE TESTING; TESTING