Published July 1, 1993
| Version v1
Report
Open
Massless gap corrections to the SDC EM energy resolution
Description
Often the calorimeter system is not the first material that particles emerging from an interaction encounter. Therefore, the problem of inert material upstream of a calorimeter is endemic. The purpose of this note is to use existing ''Hanging File = HF'' data to quantify the effect of this material and to examine ways to alleviate those effects. Previous studies have been made using CDF test beam data and using the EGS Monte Carlo program to study the electromagnetic response
Availability note (English)
MF available from INIS under the Report Number.Files
25003487.pdf
Files
(319.2 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:d5b63ae84469b3c7151e480fee280606
|
319.2 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 8 p.
- Report number
- FNAL-TM--1848
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 25003487
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- CORRECTIONS; ENERGY RESOLUTION; FERMILAB COLLIDER DETECTOR; MATERIALS; MONTE CARLO METHOD; SHOWER COUNTERS
- Descriptors DEC
- CALCULATION METHODS; MEASURING INSTRUMENTS; RADIATION DETECTORS; RESOLUTION
Optional Information
- Contract/Grant/Project number
- Contract AC02-76CH03000
- Notes
- OSTI as DE93017817; NTIS; INIS; US Govt. Printing Office Dep.
- Funding organization
- USDOE, Washington, DC (United States).