Evaluation of T2W FLAIR MR image quality using artificial intelligence image reconstruction techniques in the pediatric brain
Creators
- 1. Department of Radiology, University of Cincinnati, Cincinnati, OH (United States)
- 2. Department of Radiology and Medical Imaging, Cincinnati Children's Hospital Medical Center, 3333 Burnet Avenue, 45229-3026, Cincinnati, OH (United States)
- 3. Philips Healthcare, Cincinnati, OH (United States)
Description
Artificial intelligence (AI) reconstruction techniques have the potential to improve image quality and decrease imaging time. However, these techniques must be assessed for safe and effective use in clinical practice. To assess image quality and diagnostic confidence of AI reconstruction in the pediatric brain on fluid-attenuated inversion recovery (FLAIR) imaging. This prospective, institutional review board (IRB)-approved study enrolled 50 pediatric patients (median age=12 years, Q1=10 years, Q3=14 years) undergoing clinical brain MRI. T2-weighted (T2W) FLAIR images were reconstructed by both standard clinical and AI reconstruction algorithms (strong denoising). Images were independently rated by two neuroradiologists on a dedicated research picture archiving and communication system (PACS) to indicate whether AI increased, decreased, or had no effect on image quality compared to standard reconstruction. Quantitative analysis of signal intensities was also performed to calculate apparent signal to noise (aSNR) and apparent contrast to noise (aCNR) ratios. AI reconstruction was better than standard in 99% (reader 1, 49/50; reader 2, 50/50) for overall image quality, 99% (reader 1, 49/50; reader 2, 50/50) for subjective SNR, and 98% (reader 1, 49/50; reader 2, 49/50) for diagnostic preference. Quantitative analysis revealed significantly higher gray matter aSNR (30.6±6.5), white matter aSNR (21.4±5.6), and gray-white matter aCNR (7.1±1.6) in AI-reconstructed images compared to standard reconstruction (18±2.7, 14.2±2.8, 4.4±0.8, p<0.001) respectively. We conclude that AI reconstruction improved T2W FLAIR image quality in most patients when compared with standard reconstruction in pediatric patients.
Additional details
Identifiers
Publishing Information
- Journal Title
- Pediatric Radiology
- Journal Volume
- 54
- Journal Issue
- 8
- Journal Page Range
- p. 1337-1343
- ISSN
- 0301-0449
- CODEN
- PDRYA5
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 55079701
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ALGORITHMS; ARTIFICIAL INTELLIGENCE; BRAIN; CHILDREN; COMPARATIVE EVALUATIONS; DATA COMPILATION; IMAGE PROCESSING; NMR IMAGING; PEDIATRICS; RELAXATION TIME; REVIEWS; SIGNAL-TO-NOISE RATIO; WEIGHTING FUNCTIONS
- Descriptors DEC
- AGE GROUPS; ANIMALS; BODY; CENTRAL NERVOUS SYSTEM; DATA; DATA PROCESSING; DIAGNOSTIC TECHNIQUES; DIMENSIONLESS NUMBERS; DOCUMENT TYPES; EVALUATION; FUNCTIONS; HUMANS; INFORMATION; MAMMALS; MATHEMATICAL LOGIC; MEDICINE; NERVOUS SYSTEM; ORGANS; PRIMATES; PROCESSING; VERTEBRATES