Microdosimetric studies using a Filtered Fast Neutron Irradiation System of research reactor to application in radiation biology
Description
In this work, microdosimetric measurements were performed using a Wall-less Tissue Equivalent Proportional Counter - TEPC with spherical cavity with an inner diameter of 1.27 cm. The TEPC was tilled with pure propane gas, C3H8 at 5.6 kPa (42 Torr) pressure, which is equivalent to 1.3 μm in diameter of unit density tissue. The microdosimetric measurement device was irradiated with fast neutron radiation from Texas A and M University Nuclear Science Center research reactor, in College Station, Texas. The fast neutron beams were emitted with three different power values, 0.5, 1.0 and 2.0 kW. during 1h for both high gain and low gain, totalizing two hours for each power with 0.0083 Gy/min of dose rate. The neutron was filtered using the heavily filtered fast neutron irradiation system (FNIS). from Nuclear Science Center, to obtain a decrease of neutron radiation contamination by gamma ray and so, to gain the neutron microdosimetric spectra as. frequency distribution of lineal energy, dose distribution of lineal energy with good precision, and another quantities as frequency-mean of lineal energy, dose- mean of lineal energy, absorbed dose, equivalent dose and average quality factor of fast neutron. The obtained results were satisfactory, with the neutron microdosimetric spectra showing a gamma ray contamination under 5 %, especially to dose distribution of lineal energy. The results obtained in this work were in agreement when compared with another results from scientific literature, which used another procedure to reduce the neutron contamination by gamma ray. (author)
Files
41033664.pdf
Files
(8.4 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:4ed508538e6bf99f128d7f3cc17168b7
|
8.4 MB | Preview Download |
Additional details
Additional titles
- Original title (Portuguese)
- Estudos microdosimetricos usando um Sistema de Irradiacao de Neutrons Rapidos filtrados de reator de pesquisa para a aplicacao em radiobiologia
Publishing Information
- Imprint Pagination
- 142 p.
- Report number
- INIS-BR--6573
INIS
- Country of Publication
- Brazil
- Country of Input or Organization
- Brazil
- INIS RN
- 41033664
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Thesis
- Descriptors DEI
- BIOLOGICAL DOSEMETERS; CONTAMINATION; EVALUATION; FAST NEUTRONS; GAMMA DETECTION; IRRADIATION PROCEDURES; MICRODOSIMETRY; NEUTRON BEAMS; NEUTRON SPECTRA; PROPORTIONAL COUNTERS; RADIATION DOSE DISTRIBUTIONS; RADIOBIOLOGY; TISSUE-EQUIVALENT DETECTORS
- Descriptors DEC
- BARYONS; BEAMS; BIOLOGY; DETECTION; DOSEMETERS; DOSIMETRY; ELEMENTARY PARTICLES; FERMIONS; HADRONS; MEASURING INSTRUMENTS; NEUTRONS; NUCLEON BEAMS; NUCLEONS; PARTICLE BEAMS; RADIATION DETECTION; RADIATION DETECTORS; SPECTRA