Published 1986 | Version v1
Book

Experience with KWU steam generator tubing corrosion phenomena and their prevention

  • 1. Kraftwerk Union AG., Erlangen (Germany, F.R.)

Description

The heat transfer tubes of recirculating steam generators (SG) of pressurized water reactors (PWR) have been affected by various corrosion phenomena within the last decade. The worldwide operating experience with SG corrosion phenomena is discussed briefly and compared with the KWU experience. It shows that KWU's experience is more favourable. It is demonstrated that tubing corrosion can be minimized or even avoided by a proper design concept for steam generators in connection with a compatible secondary side concept. A proper concept must include design, selection of materials and water chemistry. (author)

Additional details

Publishing Information

Publisher
Atomic Energy Soc. of Japan.
Imprint Place
Tokyo (Japan)
Imprint Title
Proceedings of second international topical meeting on nuclear power plant thermal hydraulics and operations
Imprint Pagination
1191 p.
Journal Page Range
p. 10/24-10/30.

Conference

Title
2. international topical meeting on nuclear power plant thermal hydraulics and operations.
Dates
15-17 Apr 1986.
Place
Tokyo (Japan).