Experience with NQA-1 quality assurance standards applied to in vitro bioassay
Description
On June 1, 1990, the large (about 4,000 samples per year) excreta bioassay program at the Hanford Site ceased abruptly when the contract with the bioassay laboratory was terminated. An intense, high-priority effort was begun to replace the services on an interim basis until a new contract could be procured. Despite the urgency to get the excreta bioassay program going again, the Hanford Internal Dosimetry Program was constrained to use only labs that could meet stringent quality assurance (QA) requirements, even during the interim period. The QA requirements were based on NQA-1 with selected additions from the Environmental Protection Agency's QAMS 005/80 (EPA 1983) and the American Society for Testing and Materials' C 1009-83 (ASTM 1984). This constraint was driven both by legal reasons and by the Hanford Site contractors and workers not wanting the quality of the data to be sacrificed. Finding labs that could (1) handle the large throughput, (2) meet the technical requirements, and (3) pass the QA audit proved more difficult than first anticipated. This presentation focuses on the QA requirements that the labs had to meet and how those very broad requirements were applied specifically to excreta bioassay
Files
24014852.pdf
Files
(736.4 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:f0389b37c973ffa9e7a0b03165e3b219
|
736.4 kB | Preview Download |
Additional details
Publishing Information
- Imprint Title
- Proceedings of the third conference on radiation protection and dosimetry
- Imprint Pagination
- 169 p.
- Journal Page Range
- p. 109-116.
- Report number
- ORNL/TM--11882
Conference
- Title
- 3. conference on radiation protection and dosimetry.
- Dates
- 21-24 Oct 1991.
- Place
- Orlando, FL (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 24014852
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BIOASSAY; EXCRETION; HANFORD RESERVATION; IN VITRO; LABORATORIES; OCCUPATIONAL SAFETY; PERSONNEL DOSIMETRY; QUALITY ASSURANCE; RADIATION DOSES; RADIATION PROTECTION; STANDARDS
- Descriptors DEC
- CLEARANCE; DOSIMETRY; NATIONAL ORGANIZATIONS; PERFORMANCE TESTING; SAFETY; TESTING; US DOE; US ORGANIZATIONS
Optional Information
- Contract/Grant/Project number
- Contract AC06-76RL01830
- Secondary number(s)
- CONF-911004--.