Published 1986 | Version v1
Journal article

Fast neutron spectrometry based on proton detection in CR-39 detector

  • 1. Institute of Nuclear Research, Debrecen (Hungary)

Description

The authors have developed a home-made proton-sensitive CR-39 track detector called MA-ND/p. Using this and the n-p scattering process the performance of a fast neutron spectrometer has been studied by applying two different methods. These are based on track density determinations by using varying radiator thicknesses at constant etching time and by using varying etching times at fixed radiator thickness, respectively. For both methods studied a computer programme is made to calculate the theoretically expected neutron sensitivity as a function of neutron energy. For both methods the neutron sensitivities, expressed in terms of observable etched proton tracks per neutron, are determined experimentally for 3.3 and 14.7 MeV neutron energies. The theoretical and experimental data obtained are compared. (author)

Additional details

Publishing Information

Journal Title
Nucl. Tracks Radiat. Meas.
Journal Volume
12
Journal Issue
1-6
Series
Nucl. Tracks Radiat. Meas.
Journal Page Range
607-610
ISSN
0735-245X
CODEN
NTMRD

Conference

Title
13. international conference.
Acronym
Solid state nuclear track detectors
Dates
23-27 Sep 1985.
Place
Rome (Italy).