Published October 2014 | Version v1
Journal article

Quantification of myocardial delayed enhancement and wall thickness in hypertrophic cardiomyopathy: Multidetector computed tomography versus magnetic resonance imaging

  • 1. Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd Beijing (China)
  • 2. Department of Radiology II, Innsbruck Medical University, Innsbruck (Austria)

Description

Objectives: To evaluate the accuracy of multidetector computed tomography (MDCT) in assessing myocardial delayed enhancement and left ventricle wall thickness in hypertrophic cardiomyopathy (HCM) compared with cardiac magnetic resonance (CMR) as the reference standard. Materials and methods: Eighty consecutive patients (59 male; 53.2 ± 13.0 years) were examined with MDCT, followed by CMR 1 day later. Cardiac CT angiography and a delayed CT were performed. CMR was performed according to a standardized protocol. Left ventricle wall thickness and positions of myocardial delayed enhancement were identified in both CMR and CT images according to the American Heart Association left ventricle 17-segment model. Myocardial delayed enhancement was characterized as "dense" (areas with clear defined borders) or "diffuse" and then quantified using both techniques. Results: Left ventricle wall thickness determined by MDCT was significantly correlated with CMR (R = 0.88, P < 0.01). Compared with CMR, MDCT accurately diagnosed 74 of 78 (94.9%) patients and 1243 of 1326 (93.7%) segments. For dense myocardial delayed enhancement, MDCT significantly correlated with CMR (R = 0.88, P < 0.01) and slightly underestimated myocardial delayed enhancement (mean, −3.85%; lower and upper limits of agreement, −13.40% and 5.70%, respectively). Conclusions: MDCT provides reliable quantification of myocardial delayed enhancement and evaluation of left ventricle wall thickness and has a good correlation with CMR in patients with HCM when a comprehensive cardiac CT protocol is used and can be applied for intervention planning

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ejrad.2014.05.035

Additional details

Identifiers

DOI
10.1016/j.ejrad.2014.05.035;
PII
S0720-048X(14)00293-9;

Publishing Information

Journal Title
European Journal of Radiology
Journal Volume
83
Journal Issue
10
Journal Page Range
p. 1778-1785
ISSN
0720-048X
CODEN
EJRADR

Optional Information

Copyright
Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.