Published March 1988
| Version v1
Journal article
Diagnostic system for passive charge-exchange particle measurements on JT-60
- 1. Japan Atomic Energy Research Inst., Naka, Ibaraki. Naka Fusion Research Establishment
Description
In order to measure energy distributions of the charge-exchange neutral particles in the JT-60 experiments, a compact size electrostatic energy analyzer which the measurable energy range is from 1 keV to 100 keV is developed successfully. Compactness of an analyzer is accomplished by setting an accelerator between a gas stripping cell and a deflector of 45deg injection type. The calibration of the analyzer was carried out owing to confirm the capability of energy analysis and stripping efficiency. This analyzer was applied to measure the energy distribution in additionally heated plasmas in JT-60. The usefullness of the analyzer was confirmed. (author)
Additional details
Publishing Information
- Journal Title
- Kaku Yugo Kenkyu
- Journal Volume
- 59
- Journal Issue
- suppl
- Series
- Kaku Yugo Kenkyu.
- Journal Page Range
- 91-118
- ISSN
- 0451-2375
- CODEN
- KAKEA
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 19090559
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- CAMAC SYSTEM; CHARGE EXCHANGE; DATA PROCESSING; ELECTROSTATIC ANALYZERS; JT-60 TOKAMAK; KEV RANGE 01-10; KEV RANGE 10-100; NEUTRAL ATOM BEAM INJECTION; NEUTRAL PARTICLES; PLASMA; PLASMA DIAGNOSTICS
- Descriptors DEC
- BEAM ANALYZERS; BEAM INJECTION; CLOSED PLASMA DEVICES; ENERGY RANGE; KEV RANGE; THERMONUCLEAR DEVICES; TOKAMAK DEVICES