The first-in-human preclinical evaluation of the new probe [123I]I-PSMA-7 for real-time intraoperative targeted biopsy and SPECT/CT imaging in prostate cancer
Creators
- 1. Chinese PLA General Hospital, Chinese PLA Medical School, Beijing (China)
- 2. Department of Nuclear Medicine, The First Medical Centre of Chinese PLA General Hospital, Beijing (China)
- 3. Department of Urology, The Third Medical Centre of Chinese PLA General Hospital, Beijing (China)
- 4. Key Laboratory of Radiopharmaceuticals, Ministry of Education, College of Chemistry, Beijing Normal University, Beijing (China)
Description
PSMA/PET has been increasingly used to detect PCa, and PSMA/PET-guided biopsy has shown promising results. However, it cannot be confirmed immediately whether the tissues are the targeted area. In this study, we aimed to develop a novel probe, [I]I-PSMA-7. First, we hope that [I]I-PSMA-7 can provide instant confirmation for prostate biopsy. Second, we hope it will help detect PCa. We synthesized a high-affinity probe, [I]I-PSMA-7, and evaluated its properties. We included ten patients with suspected PCa and divided them into two groups. The injection and biopsy were approximately 24 h apart. The activity in biopsy lesions was measured as the cpm by a γ-counter. Moreover, we enrolled 3 patients to evaluate the potential of [I]I-PSMA-7 for detecting PCa. Animal experiments verified the safety, targeting and effectiveness of [I]I-PSMA-7, and the tumor-to-muscle ratio was greatest at 24 h, which confirmed the results of this study in humans. After injection of 185MBq [I]I-PSMA-7, 18/55 cores were positive, and the cpm was significantly greater (4345 ± 3547 vs. 714 ± 547, P < 0.001), with an AUC of 0.97 and a cutoff of 1312 (sens/spec of 94.40%/91.90%). At a lower dose, 10/55 biopsy cores were cancerous, and the cpm was 2446 ± 1622 vs. 153 ± 112 (P < 0.001). The AUC was 1, with a cutoff value of 490 (sens/spec of 100%). When the radiopharmaceuticals were added to 370 MBq, we achieved better SPECT/CT imaging. With the aid of [I]I-PSMA-7 and via cpm-based biopsy, we can reduce the number of biopsies to a minimum operation. [I]I-PSMA-7 PSMA SPECT/CT can also provide good imaging results.
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00259-024-06833-4Additional details
Identifiers
Publishing Information
- Journal Title
- European Journal of Nuclear Medicine and Molecular Imaging
- Journal Volume
- 51
- Journal Issue
- 13
- Journal Page Range
- p. 4141-4150
- ISSN
- 1619-7070
- CODEN
- EJNMA6
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 56000463
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ANTIGENS; BIOLOGICAL ACCUMULATION; BIOPSY; CARCINOMAS; DATA COMPILATION; GAMMA DETECTION; HUMANS; INJECTION; IODINE 123; MEGA BQ RANGE 100-1000; MUSCLES; POSITRON COMPUTED TOMOGRAPHY; PROSTATE; QUALITY CONTROL; RADIATION DOSES; RADIOPHARMACEUTICALS; SAFETY; SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY; TOXICITY
- Descriptors DEC
- ANIMALS; BETA DECAY RADIOISOTOPES; BODY; COMPUTERIZED TOMOGRAPHY; CONTROL; DATA; DATA PROCESSING; DETECTION; DIAGNOSTIC TECHNIQUES; DISEASES; DOSES; DRUGS; ELECTRON CAPTURE RADIOISOTOPES; EMISSION COMPUTED TOMOGRAPHY; GLANDS; HOURS LIVING RADIOISOTOPES; INFORMATION; INTAKE; INTERMEDIATE MASS NUCLEI; IODINE ISOTOPES; ISOTOPES; LABELLED COMPOUNDS; MALE GENITALS; MAMMALS; MATERIALS; MEGA BQ RANGE; NEOPLASMS; NUCLEI; ODD-EVEN NUCLEI; ORGANS; PRIMATES; PROCESSING; RADIATION DETECTION; RADIOACTIVE MATERIALS; RADIOACTIVITY RANGE; RADIOISOTOPES; TOMOGRAPHY; VERTEBRATES