Calibration for the ATLAS Level-1 Calorimeter-Trigger

Description

This thesis describes developments and tests that are necessary to operate the Pre-Processor of the ATLAS Level-1 Calorimeter Trigger for data acquisition. The major tasks of Pre-Processor comprise the digitizing, time-alignment and the calibration of signals that come from the ATLAS calorimeter. Dedicated hardware has been developed that must be configured in order to fulfill these tasks. Software has been developed that implements the register-model of the Pre-Processor Modules and allows to set up the Pre-Processor. In order to configure the Pre-Processor in the context of an ATLAS run, user-settings and the results of calibration measurements are used to derive adequate settings for registers of the Pre-Processor. The procedures that allow to perform the required measurements and store the results into a database are demonstrated. Furthermore, tests that go along with the ATLAS installation are presented and results are shown. (orig.)

Availability note (English)

Available from INIS in electronic form

Files

39079762.pdf

Files (31.1 MB)

Name Size Download all
md5:96170bf80102645e7985329c3735d0f6
31.1 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
127 p.
Report number
INIS-DE--0405