Published 1990 | Version v1
Book

Tracking with the ALEPH time projection chamber

Description

This paper reports on the tracking performance of the ALEPH Time Projection Chamber (TPC) studied using the data taken during the LEP running periods in 1989 and 1990. After careful correction of residual distortions and optimization of coordinate reconstruction algorithms a single coordinate resolution of 173 μm in azimuthal and 740 μm in longitudinal direction is achieved. This results in a momentum resolution for the TPC alone of Δp/p2 = 0.0012 (GeV/c)-1. In combination with the ALEPH Inner Tracking Chamber (ITC) a total momentum resolution of Δp/p2 = 0.0008 (GeV/c)-1, close to the design specifications is reached

Additional details

Publishing Information

Publisher
IEEE Service Center.
Imprint Place
Piscataway, NJ (USA)
Imprint Title
IEEE nuclear science symposium conference record emdash 1990
Imprint Pagination
1636 p.
Journal Page Range
p. 753-761.

Conference

Title
1990 Institute of Electrical and Electronics Engineers (IEEE) nuclear science symposium.
Dates
22-27 Oct 1990.
Place
Arlington, VA (USA).

INIS

Optional Information

Secondary number(s)
CONF-9010220--.