Published September 1996
| Version v1
Report
Identification of potential rupture locations at the high-pressure emergency core cooling system piping within loop no. 2 of unit 1 of the Mochovce NPP
Description
The static and seismic calculation was performed for the segment from the cold leg socket to the steam generator box penetration. The rupture analysis was based on the procedure specified by the Standard Review Plan 3.6.2 for safety class 1 piping. It was found that the piping segment satisfies requirements of the relevant standard of the Association of Mechanical Engineers in normal operating conditions and does not exceed the rupture criteria as per Standard Review Plan 3.6.2 along its entire length; hence, rupture has only to be postulated in the locations of attachment to the socket and to the pressurizer upper lid
Availability note (English)
Available from Nuclear Research Institute Rez plc, 250 68 Rez, Czech RepublicAdditional details
Additional titles
- Original title (Czech)
- Urceni potencialnich mist roztrzeni potrubi VT SAOZ smycky c. 2 EMO, blok 1
Publishing Information
- Imprint Pagination
- 29 p.
- Report number
- UJV--10756-T
INIS
- Country of Publication
- Czech Republic
- Country of Input or Organization
- Czech Republic
- INIS RN
- 29053736
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Non-conventional Literature
- Descriptors DEI
- DESIGN BASIS ACCIDENTS; DYNAMIC LOADS; ECCS; MOCHOVCE-1 REACTOR; PIPES; REACTOR SAFETY; RUPTURES; STRESS ANALYSIS; STRESSES
- Descriptors DEC
- ACCIDENTS; ENGINEERED SAFETY SYSTEMS; ENRICHED URANIUM REACTORS; FAILURES; POWER REACTORS; PWR TYPE REACTORS; REACTOR ACCIDENTS; REACTOR PROTECTION SYSTEMS; REACTORS; SAFETY; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS; WWER TYPE REACTORS
Optional Information
- Notes