Published 1975
| Version v1
Report
Open
HPD measurements for determination of the ''Mirabelle'' optical constants
Creators
- 1. Gosudarstvennyj Komitet po Ispol'zovaniyu Atomnoj Ehnergii SSSR, Serpukhov. Inst. Fiziki Vysokikh Ehnergij
Description
The capabilities and advantages of using HPD in the procedure of optical constant determination for the hydrogen bubble chamber Mirabelle have been shown. The features of using HPD for measuring the fiducial marks have been described. The results on calculating the optical constants obtained with HPD measurements are presented being compared with those obtained from conventional manual measurements
Availability note (English)
MF available from INIS under the Report Number.Files
7279326.pdf
Files
(317.0 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:b46702b6f5e919ff25c9d9d8e5b11937
|
317.0 kB | Preview Download |
System files
(29.7 kB)
| Name | Size | Download all |
|---|
Additional details
Additional titles
- Original title (Russian)
- Использование HPD в процедуре определения оптических констант камеры ''Мирабельь
Publishing Information
- Imprint Pagination
- 16 p.
- Report number
- IFVE-PPK-OMVT--75-147
INIS
- Country of Publication
- USSR
- Country of Input or Organization
- USSR
- INIS RN
- 7279326
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ACCURACY; BUBBLE CHAMBERS; CALIBRATION; COMPARATIVE EVALUATIONS; IMAGE SCANNERS; OPTICAL DEPTH CURVE; TABLES; TIME DEPENDENCE; USES
- Descriptors DEC
- DIAGRAMS; GAS TRACK DETECTORS; INFORMATION; MEASURING INSTRUMENTS; RADIATION DETECTORS
Optional Information
- Notes
- 7 refs.; 7 figs.