HPD measurements for determination of the ''Mirabelle'' optical constants

  • 1. Gosudarstvennyj Komitet po Ispol'zovaniyu Atomnoj Ehnergii SSSR, Serpukhov. Inst. Fiziki Vysokikh Ehnergij

Description

The capabilities and advantages of using HPD in the procedure of optical constant determination for the hydrogen bubble chamber Mirabelle have been shown. The features of using HPD for measuring the fiducial marks have been described. The results on calculating the optical constants obtained with HPD measurements are presented being compared with those obtained from conventional manual measurements

Availability note (English)

MF available from INIS under the Report Number.

Files

7279326.pdf

Files (317.0 kB)

Name Size Download all
md5:b46702b6f5e919ff25c9d9d8e5b11937
317.0 kB Preview Download

System files (29.7 kB)

Name Size Download all

Additional details

Additional titles

Original title (Russian)
Использование HPD в процедуре определения оптических констант камеры ''Мирабельь

Publishing Information

Imprint Pagination
16 p.
Report number
IFVE-PPK-OMVT--75-147

Optional Information

Notes
7 refs.; 7 figs.