Published March 2012 | Version v1
Report

Development of reactor water level sensor for extreme conditions

  • 1. Sukegawa Electric Co., Ltd., Hitachi, Ibaraki (Japan)
  • 2. Japan Atomic Energy Agency, Oarai Research and Development Center, Oarai, Ibaraki (Japan)

Description

In the Fukushima accident, measurement failure of water level was one of the most important factors which caused serious situation. The differential pressure type water level indicators are widely used in various place of nuclear power plant but after the accident of TMI-2, the need of other reliable method has been required. The BICOTH type and the TRICOTH type water level indicator for light water power reactors had been developed for in-pile water level indicator but currently those are not adopted to nuclear power plant. In this study, the development of new type water level indicator composed of thermocouple and heater is described. Demonstration test and characteristic evaluation of the water level indicator were performed and we had obtained satisfactory results. (author)

Part of:
Proceedings of the 4th international symposium on material testing reactors

Additional details

Publishing Information

Imprint Title
Proceedings of the 4th international symposium on material testing reactors
Imprint Pagination
310 p.
Journal Page Range
p. 193-195
Report number
JAEA-Conf--2011-003

Conference

Title
4. international symposium on material testing reactors
Dates
5-9 Dec 2011
Place
Oarai, Ibaraki (Japan)

Optional Information

Notes
3 refs., 4 figs.