Analysis of patients receiving ≥ 100 mSv during a computed tomography intervention
- 1. Radiology Department, Massachusetts General Hospital, 55 Fruit Street, 02114, Boston, MA (United States)
Description
To identify a patient cohort who received ≥ 100 mSv during a single computed tomography (CT)-guided intervention and analyze clinical information. Using the dose-tracking platform Radimetrics that collects data from all CT scanners in a single hospital, a patient-level search was performed retrospectively by setting a threshold effective dose (E) of 100 mSv for the period from January 2013 to December 2017. Patients who received ≥ 100 mSv in a single day during a single CT-guided intervention were then identified. Procedure types were identified, and medical records were reviewed up to January 2020 to identify patients who developed short- and/or medium-term (up to 8 years) medical consequences. Of 8952 patients with 100 mSv+, there were 33 patients who underwent 37 CT-guided interventions each resulting in ≥ 100 mSv. Procedures included ablations (15), myelograms (8), drainages (7), biopsies (6), and other (1). The dose for individual procedures was 100.2 to 235.5 mSv with mean and median of 125.7 mSv and 111.8 mSv, respectively. Six patients (18 %) were less than 50 years of age. During the study period of 0.2 to 7 years, there were no deterministic or stochastic consequences identified in this study cohort. While infrequent, CT-guided interventions may result in a single procedure dose of ≥ 100 mSv. Awareness of the possibility of such high doses and potential for long-term deleterious effects, especially in younger patients, and consideration of alternative imaging guidance and/or further dose optimization should be strongly considered whenever feasible.
Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 31
- Journal Issue
- 5
- Journal Page Range
- p. 3065-3070
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 52086349
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE; S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- ABLATION; BIOLOGICAL RADIATION EFFECTS; BIOPSY; COMPUTERIZED TOMOGRAPHY; DRAINAGE; EFFECTIVE RADIATION DOSES; MEDICAL RECORDS; MILLI SV RANGE 100-1000; MILLI SV RANGE 10-100; OPTIMIZATION; RADIATION HAZARDS; RADIATION PROTECTION; SAFETY; STOCHASTIC PROCESSES
- Descriptors DEC
- BIOLOGICAL EFFECTS; DIAGNOSTIC TECHNIQUES; DOSES; EQUIVALENT DOSE RANGE; HAZARDS; HEALTH HAZARDS; MILLI SV RANGE; RADIATION DOSE RANGES; RADIATION DOSES; RADIATION EFFECTS; TOMOGRAPHY