Published September 22, 1986
| Version v1
Report
Open
Dispersive effects of transverse magnet displacements in rolled arc achromats
Description
The effect of transverse displacements of combined function magnets is investigated where the disperion in not matched due to roll. This dispersion function is perturbed by displacement of combined function magnets either singly or coherently. In the latter case the effect of a systematic (or DC) offset of magnets is examined. This type of error can occur due to systematics in the placement or the readout of Beam Position Monitors or equivalently by correcting the orbit of a beam of the wrong momentum with respect to the Arc magnet excitation. 5 refs., 18 figs
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01; 1 as DE87000189.Files
18052197.pdf
Files
(357.1 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:fa95728207ffb87084bbbc5893f195a0
|
357.1 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 17 p.
- Report number
- SLAC-CN--343
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 18052197
- Subject category
- S43: PARTICLE ACCELERATORS;
- Descriptors DEI
- BEAM OPTICS; COMPUTERIZED SIMULATION; DISPERSION RELATIONS; MAGNETS
- Descriptors DEC
- EQUIPMENT; SIMULATION
Optional Information
- Notes
- Portions of this document are illegible in microfiche products.