Published November 2011 | Version v1
Journal article

Calcium scoring in unenhanced and enhanced CT data of the aorta-iliacal arteries: impact of image acquisition, reconstruction, and analysis parameter settings

  • 1. Dept. of Surgery, Univ. Hospital Antwerp, Edegem (Belgium)
  • 2. Dept. of Surgery, Univ. Medical Center Rotterdam, Erasmus MC, Rotterdam (Netherlands)
  • 3. Dept. of Radiology, Univ. Medical Center Rotterdam, Erasmus MC, Rotterdam (Netherlands)
  • 4. Dept. of Neurosciences and Anatomy, Univ. Medical Center Rotterdam, Erasmus MC, Rotterdam (Netherlands)

Description

Background. Several studies have been published on the matter of abdominal aortic and iliac calcifications and the association to clinical entities such as diabetes mellitus and renal failure. However, comparing of these studies is questionable since quantification methods for atherosclerosis differ. Purpose. To evaluate the effect of image acquisition settings, reconstruction parameters, and analysis methods on calcium quantification in the abdominal aorta. Material and Methods. Calcium scores were retrospectively determined on standardized abdominal CT scans of 15 patients. Two researchers obtained calcium scores with 10 different lower thresholds (LT) (130, 145, 160, 175, 200, 300, 400, 500, 600, 1000) in CT scans with and without contrast enhancement, with slice thicknesses (ST) varying between 2.0-5.0 mm for the non-contrast-enhanced series and between 1.0-5.0 mm for the contrast-enhanced series. In addition calcium scores obtained with two convolution kernels (B10f, B20f) were compared. Inter-observer variability was calculated. Results. Calcium scoring at higher STs is overestimated compared to smaller STs and this effect was more pronounced with increasing calcium loads. Concerning the convolution kernel, scores obtained with kernel B10f were overestimated compared to kernel B20f. Increase of LT resulted in a decrease of the calcium score and scoring in contrast-enhanced series resulted in higher scores compared to non-contrast-enhanced series. These effects are more apparent in patients with higher calcium loads. Calcium scoring reproducibility with the reference standard is limited for the aorta-iliac trajectory, whereas scoring with the remaining settings is reproducible. Conclusion. Scores obtained with different settings cannot be compared. The inter-observer reproducibility was limited using the reference standard and practical difficulties were substantial. Scoring with higher LT, ST, and contrast enhancement is faster and has less practical difficulties

Availability note (English)

Available from DOI: http://dx.doi.org/10.1258/ar.2011.110189

Additional details

Identifiers

Publishing Information

Journal Title
Acta Radiologica (online)
Journal Volume
52
Journal Issue
9
Journal Page Range
p. 943-950
ISSN
1600-0455

INIS

Country of Publication
Sweden
Country of Input or Organization
Sweden
INIS RN
43003419
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ARTERIES; CALCIUM; COMPUTERIZED TOMOGRAPHY; CONTRAST MEDIA; DATA; IMAGES
Descriptors DEC
ALKALINE EARTH METALS; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; ELEMENTS; INFORMATION; METALS; ORGANS; TOMOGRAPHY