It was discussed in this article that different monitors' effect on the cross section measurements of nuclear reactions induced by 14 MeV neutrons, at the same time some monitors and correlative parameters were listed. The excitation functions of monitors are taken from the evaluated cross sections, and a qualitative analysis has been performed for 27Al(n, p) 27Mg reaction. It indicates that the choice of monitor is very important for cross section measurements. (authors)
Additional details
Publishing Information
- Journal Title
- Nuclear Physics Review
- Journal Volume
- 23
- Journal Issue
- 3
- Journal Page Range
- p. 296-299
- ISSN
- 1007-4627
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 38065626
- Subject category
- S73: NUCLEAR PHYSICS AND RADIATION PHYSICS;
- Descriptors DEI
- ALUMINIUM 27 TARGET; CROSS SECTIONS; EXCITATION FUNCTIONS; MAGNESIUM 27; MEV RANGE 10-100; NEUTRON FLUENCE; NEUTRON MONITORS; NEUTRON REACTIONS; PROTONS
- Descriptors DEC
- ALKALINE EARTH ISOTOPES; BARYON REACTIONS; BARYONS; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; CROSS SECTIONS; DIFFERENTIAL CROSS SECTIONS; ELEMENTARY PARTICLES; ENERGY RANGE; EVEN-ODD NUCLEI; FERMIONS; FUNCTIONS; HADRON REACTIONS; HADRONS; ISOTOPES; LIGHT NUCLEI; MAGNESIUM ISOTOPES; MEASURING INSTRUMENTS; MEV RANGE; MINUTES LIVING RADIOISOTOPES; MONITORS; NUCLEAR REACTIONS; NUCLEI; NUCLEON REACTIONS; NUCLEONS; RADIATION MONITORS; RADIOISOTOPES; TARGETS
Optional Information
- Notes
- 1 fig., 1 tab., 17 refs.