Published 2007 | Version v1
Report Open

TRIGA reactor main systems

  • 1. Atomic Insititute of the Austrian Universities, Stadionallee 2, 1020 Vienna (Austria)

Description

This module describes the main systems of low power (<2 MW) and higher power (≥2 MW) TRIGA reactors. The most significant difference between the two is that forced reactor cooling and an emergency core cooling system are generally required for the higher power TRIGA reactors. However, those TRIGA reactors that are designed to be operated above 3 MW also use a TRIGA fuel that is specifically designed for those higher power outputs (3 to 14 MW). Typical values are given for the respective systems although each TRIGA facility will have unique characteristics that may only be determined by the experienced facility operators. Due to the inherent wide scope of these research reactor facilities construction and missions, this training module covers those systems found at most operating TRIGA reactor facilities but may also discuss non-standard equipment that was found to be operationally useful although not necessarily required. (author)

Availability note (English)

Available from INIS in electronic form; Also available from Atominstitut der Oesterreichischen Universitaeten, Stadionallee 2, Vienna (AT)