Measurements and standards for determining the permanent magnet properties of rare earth cobalt magnets

Creators

  • 1. Sunderland Polytechnic (United Kingdom). Magnet Centre

Description

The standard method of measurement of the demagnetization curve of rare earth cobalt magnets is outlined. This involves external magnetization, assembly in an electromagnet and plotting of the curve with an X-Y recorder to form a hysteresigraph. The precautions to be taken and the errors and uncertainties of measurements and of the alternative standards are considered. (Author)

Part of:
Proceedings of the sixth international workshop on rare earth-cobalt permanent magnets and their applications, August 31 - September 2, 1982, and third international symposium on magnetic anisotropy and coercivity in rare earth-transition metal alloys, September 3, 1982

Additional details

Publishing Information

Publisher
Technical University.
Imprint Place
Vienna (Austria)
Imprint Title
Proceedings of the sixth international workshop on rare earth-cobalt permanent magnets and their applications, August 31 - September 2, 1982, and third international symposium on magnetic anisotropy and coercivity in rare earth-transition metal alloys, September 3, 1982
Imprint Pagination
802 p.
Journal Page Range
p. 277-285.
Report number
RCO--6

Conference

Title
6. international workshop on rare earth-cobalt permanent magnets and their applications.
Dates
31 Aug - 2 Sep 1982.
Place
Baden (Austria).

INIS

Country of Publication
Austria
Country of Input or Organization
Austria
INIS RN
14795066
Subject category
S36: MATERIALS SCIENCE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
COBALT BASE ALLOYS; HYSTERESIS; MAGNETIC PROPERTIES; MAGNETIZATION; MEASURING METHODS; PERMANENT MAGNETS; RARE EARTH ALLOYS
Descriptors DEC
ALLOYS; COBALT ALLOYS; EQUIPMENT; MAGNETIC MOMENTS; MAGNETS; PHYSICAL PROPERTIES; TRANSITION ELEMENT ALLOYS

Optional Information