Linearity of the air kerma values in relation to exposure times in a dental X radiation system

  • 1. nstituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

Description

The objective of this study was the evaluation of a dental X radiation system intensity variation studying the linearity of the air kerma rate in relation to the exposure time. This study was performed in a Dabi Atlante dental X radiation system. For the exposure time measurements the cone spacer was positioned perpendicular to the detector and the time was varied from 0 to 1.5 s. The air kerma measurements were made in the same conditions for FDD=20.0 cm and 27.5 cm. After that, the obtained values were plotted and a linear adjust was done for each set of measurements. The results showed that the maximum variation obtained was 7% for the third group of measurements for the exposure time of 1.5 s. This variation is less than the recommended limit of 20% published by the Brazilian Health Ministry Regulation 453. (author)

Part of:
Proceedings of the INAC 2007 International nuclear atlantic conference. Nuclear energy and energetic challenges for 21st. century. 15. Brazilian national meeting on reactor physics and thermal hydraulics; 8. Brazilian national meeting on nuclear applications

Additional details

Publishing Information

ISBN
978-85-99141-02-1
Imprint Title
Proceedings of the INAC 2007 International nuclear atlantic conference. Nuclear energy and energetic challenges for 21st. century. 15. Brazilian national meeting on reactor physics and thermal hydraulics; 8. Brazilian national meeting on nuclear applications
Imprint Pagination
[vp.]
Journal Page Range
[5 p.]

Conference

Title
INAC 2007 International nuclear atlantic conference. Nuclear energy and energetic challenges for 21st. century. 15. Brazilian national meeting on reactor physics and thermal hydraulics; 8. Brazilian national meeting on nuclear applications
Dates
30 Sep - 5 Oct 2007
Place
Santos, SP (Brazil)

INIS

Country of Publication
Brazil
Country of Input or Organization
Brazil
INIS RN
39086824
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
AIR; KERMA; QUALITY ASSURANCE; RADIATION DOSES; RADIATION PROTECTION; SAFETY STANDARDS; TIME DEPENDENCE; X RADIATION; X-RAY TUBES
Descriptors DEC
DOSES; ELECTROMAGNETIC RADIATION; ELECTRON TUBES; EQUIPMENT; FLUIDS; GASES; IONIZING RADIATIONS; RADIATIONS; STANDARDS; X-RAY EQUIPMENT

Optional Information

Notes
5 refs., 3 figs., 3 tabs. Code: E02_1.710pdf