Published October 19, 2015 | Version v1
Journal article

Flux-coherent series SQUID array magnetometers operating above 77 K with superior white flux noise than single-SQUIDs at 4.2 K

  • 1. Department of Physics, Loughborough University, Loughborough LE11 3TU (United Kingdom)
  • 2. School of Physics and Astronomy, Nottingham University, Nottingham NG7 2RD (United Kingdom)

Description

A very promising direction to improve the sensitivity of magnetometers based on superconducting quantum interference devices (SQUIDs) is to build a series-array of N non-interacting SQUIDs operating flux-coherently, because in this case their voltage modulation depth, ΔV, linearly scales with N whereas the white flux noise SΦ1/2 decreases as 1/N1/2. Here, we report the realization of both these improvements in an advanced layout of very large SQUID arrays made of YBa2Cu3O7. Specially designed with large area narrow flux focusers for increased field sensitivity and improved flux-coherency, our arrays have extremely low values for SΦ1/2 between (0.25 and 0.44) μΦ0/Hz1/2 for temperatures in the range (77–83) K. In this respect, they outperform niobium/aluminium trilayer technology-based single-SQUIDs operating at 4.2 K. Moreover, with values for ΔV and transimpedance in the range of (10–17) mV and (0.3–2.5) kΩ, respectively, a direct connection to a low-noise room temperature amplifier is allowed, while matching for such readout is simplified and the available bandwidth is greatly increased. These landmark performances suggest such series SQUID arrays are ideal candidates to replace single-SQUIDs operating at 4.2 K in many applications

Additional details

Identifiers

Publishing Information

Journal Title
Applied Physics Letters
Journal Volume
107
Journal Issue
16
Journal Page Range
p. 162602-162602.5
ISSN
0003-6951
CODEN
APPLAB

Optional Information

Notes
(c) 2015 AIP Publishing LLC