Experiment to measure the effects of biaxial strain on the critical current of NbTi superconductor
Description
Twisted multifilament, copper-clad NbTi superconductors have been axially and biaxially strained at 4.2K with a 7.5T background field. A simply-constructed cryogenic loading frame was built and used to strain the conductor. Results on 1.27 mm x 3.13 mm conductor have shown that degradation of less than .3 percent of critical current occurred when the wire was biaxially strained to +3260 μepsilon in the axial direction and -1875 μepsilon in the transverse direction. Degradation approaches 3 percent of critical current at approximately 6000 μepsilon in the axial direction only
Availability note (English)
MF available from INIS under the Report Number.
Files
Additional details
Publishing Information
- Imprint Pagination
- 4 p.
- Report number
- CONF-751125--36
Conference
- Title
- IEEE 6. symposium on engineering problems of fusion research.
- Dates
- 17 Nov 1975.
- Place
- San Diego, California, USA.
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 7234723
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY; S75: CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CRITICAL CURRENT; NIOBIUM ALLOYS; STRAINS; SUPERCONDUCTING CABLES; TITANIUM ALLOYS