The recently developed praseodymium-doped lutetium aluminum garnet, LuAG(Pr), holds a strong potential for fast timing applications. In this study we report on the time response of LuAG(Pr) at 22Na and 60Co photon energies. The measurements were performed using a small crystal cube of 1 cm3 coupled to a Hamamatsu R5320 photomultiplier tube. The full width at half maximum (FWHM) time resolution is found to be 147±2 ps at 60Co energies, and 238±2 ps at 22Na