Media glandular dose in mammography
Creators
- 1. Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)
- 2. IPN, Centro de Investigacion en Ciencia Aplicada en Tecnologia Avanzada, Av. Legaria 694, 11500 Mexico D. F. (Mexico)
- 3. Universidad Autonoma Metropolitana, Unidad Iztapalapa, Av. San Rafael Atlixco 186, 09340 Mexico D. F. (Mexico)
Description
The objective of this work was to determine the media glandular dose of the patients group who most frequently are exposed at mammographic studies in the General Hospital of Zone No. 1 of IMSS in Zacatecas, later to compare this dose with the value that establishes the Mexican Official Standard and to know risk-benefit that a patient is exposed when it is realized studies of this nature. This with the purpose of to know if the patients who are realized this type of studies are exhibited to irradiations of unnecessary way. In order to obtain the media glandular dose, first it was choose the age group of feminine population that is predominant to this suffering. Of the classification of the age group it was determine the frequency of each thickness of mamma, and on the basis of the thickness of the compressed mamma the conditions were registered with it radiates the patient. When having the age and compressed mamma thickness of patient and the voltage, current, anode/filter that uses the mammography equipment for to radiate it was calculated the media glandular dose. The media glandular dose was calculated using two algorithms proposed in literature and thermoluminescent dosemeters. For the case of the thermoluminescent dosemeters were used two phantoms. In this study was detected that the limits, with that they radiate the patients who are exposed at mammographic studies it is by underneath of 3 mGy. Finally, it was detected that the Mexican Official Standard lacks of elements to offer radiological limits for the mammography area, because in this standard they are excluded the radiological limits for anode and filter of Mo/Rh and Rh/Rh. To know the dose applying these anodes and filters is of extreme importance because 85% of the population that is exposed to this studies type was radiated with anode and filter of Mo/Rh and Rh/Rh. (Author)
Availability note (English)
Available from the Instituto Nacional de Investigaciones Nucleares, Centro de Informacion y Documentacion, 52750 Ocoyoacac, Estado de Mexico (MX), e-mail: javier.ortega@inin.gob.mx; claudio.fernandez@inin.gob.mxAdditional details
Additional titles
- Original title (Spanish)
- Dosis glandular media en mamografia
Publishing Information
- Publisher
- Sociedad Nuclear Mexicana
- Imprint Place
- Mexico D. F. (Mexico)
- ISBN
- 978-607-95174-0-3
- Imprint Pagination
- 14 p.
Conference
- Title
- trends of the nuclear energy
- Original Conference Title
- 20. Congreso Anual de la SNM: perspectivas y retos de la energia nuclear
- Acronym
- 20. SNM Annual Congress
- Dates
- 5-8 Jul 2009
- Place
- Puerto Vallarta, Jal. (Mexico)
INIS
- Country of Publication
- Mexico
- Country of Input or Organization
- Mexico
- INIS RN
- 41079568
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- AGE GROUPS; ALGORITHMS; ANODES; BIOMEDICAL RADIOGRAPHY; COMPARATIVE EVALUATIONS; HOSPITALS; IRRADIATION; MAMMARY GLANDS; MEXICO; PATIENTS; PHANTOMS; STANDARDS; THERMOLUMINESCENT DOSEMETERS
- Descriptors DEC
- BODY; BUILDINGS; DEVELOPING COUNTRIES; DIAGNOSTIC TECHNIQUES; DOSEMETERS; ELECTRODES; EVALUATION; GLANDS; LATIN AMERICA; LUMINESCENT DOSEMETERS; MATHEMATICAL LOGIC; MEASURING INSTRUMENTS; MEDICAL ESTABLISHMENTS; MEDICINE; MOCKUP; NORTH AMERICA; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; STRUCTURAL MODELS