Published June 1994 | Version v1
Journal article

Sensitivity calculation of PIN neutron detector system with thick absorber

  • 1. Academia Sinica, Lanzhou, GS (China). Inst. of Modern Physics

Description

A method of calculating sensitivity of PIN neutron detector system with a thick absorber simulation has been put forward. The program LPMC (Layers and Pieces with Monte-Carlo) was written in FORTRAN 77 language. The error of the calculation is not more than 1.88%. The results from LPMC calculation are in agreement with the experiments within the above error, thus the shortcoming of over-deviations for the LP calculation has been avoided

Additional details

Publishing Information

Journal Title
Nuclear Techniques
Journal Volume
17
Journal Issue
6
Journal Page Range
p. 351-355.
ISSN
0253-3219
CODEN
NUTEDL