Published September 2018 | Version v1
Journal article

Comparison of experimental and calculated shielding factors for modular buildings in a radioactive fallout scenario

  • 1. Technical University of Denmark, Center for Nuclear Technologies (Denmark)
  • 2. Lund University, Department of Translational Medicine, Medical Radiation Physics (Sweden)

Description

Highlights: • The applicability of MCNP6 for radioactive fallout scenarios was demonstrated. • The accuracy of construction materials is of importance for the building model. • The agreement of calculated and measured shielding factor is independent of energy. • The shielding effect for 137Cs and 134Cs was determined to be almost the same. - Abstract: Experimentally and theoretically determined shielding factors for a common light construction dwelling type were obtained and compared. Sources of the gamma-emitting radionuclides 60Co and 137Cs were positioned around and on top of a modular building to represent homogeneous fallout. The modular building used was a standard prefabricated structure obtained from a commercial manufacturer. Four reference positions for the gamma radiation detectors were used inside the building. Theoretical dose rate calculations were performed using the Monte Carlo code MCNP6, and additional calculations were performed that compared the shielding factor for 137Cs and 134Cs. This work demonstrated the applicability of using MCNP6 for theoretical calculations of radioactive fallout scenarios. Furthermore, the work showed that the shielding effect for modular buildings is almost the same for 134Cs as for 137Cs.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.jenvrad.2018.04.005

Additional details

Identifiers

DOI
10.1016/j.jenvrad.2018.04.005;
PII
S0265931X18300729;

Publishing Information

Journal Title
Journal of Environmental Radioactivity
Journal Volume
189
Journal Page Range
p. 146-155
ISSN
0265-931X
CODEN
JERAEE

Optional Information

Notes
© 2018 Elsevier Ltd. All rights reserved.