Published July 2009 | Version v1
Book

Evaluation of Alumina Based 188W/188Re Chromatographic Generators

  • 1. Isotope Centre (CENTIS), Havana (Cuba)

Description

Within the framework of the coordinated research project, different alumina based 188W/188Re chromatographic generators were prepared and evaluated. The 188W activities loaded into the generators ranged from 200 to 400 mCi, and two different amounts of alumina (2 and 8 g) were used. The lowest 188W breakthrough levels were obtained for the generator containing 8 g of alumina, while the best elution profile corresponded to the 2 g alumina generators. Regarding elution efficiency, the performance of all generators was similar and ranged from 70 to 80% yields of 188Re. The eluate quality was evaluated through the labelling of monoclonal antibodies and diphosphonates. (author)

Part of:
Therapeutic Radionuclide Generators: 90Sr/90Y and 188W/188Re Generators

Additional details

Publishing Information

Publisher
IAEA
Imprint Place
Vienna (Austria)
ISBN
978-92-0-111408-2
Imprint Title
Therapeutic radionuclide generators: "9"0Sr/"9"0Y and "1"8"8W/"1"8"8Re generators
Imprint Pagination
248 p.
Journal Issue
no. 470
Series
Technical Reports Series
Journal Page Range
p. 113-117
ISSN
0074-1914

Optional Information

Notes
1 ref, 3 figs
Secondary number(s)
STI/DOC--010/470