Published October 1980 | Version v1
Journal article

Radium needle spacing effect on the dose distribution of planar implants

  • 1. Ellis Fischel State Cancer Hospital and State Research Inst., Columbia, MO (USA)

Description

The dose distribution of planar radium implants consisting of a number of parallel needles (PN) with a crossing needle (CN) at one end was studied. The fraction of the implant area receiving 85% of the maximum dose is plotted against the distance of the CN beyond the active ends of the PN, for different PN spacings. The optimum dose distribution occurs when the CN is located at the physical ends of the implant. Reduced PN spacing increases the dose rate at 85% of maximum dose and improves the dose coverage over the whole range of CN locations plotted. (author)

Additional details

Publishing Information

Journal Title
Br. J. Radiol.
Journal Volume
53
Journal Issue
634
Series
Br. J. Radiol.
Journal Page Range
996-997
ISSN
0007-1285

INIS

Country of Publication
United Kingdom
Country of Input or Organization
United Kingdom
INIS RN
12592166
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
GEOMETRY; RADIATION SOURCE IMPLANTS; RADIOTHERAPY; RADIUM; SPATIAL DISTRIBUTION; SPATIAL DOSE DISTRIBUTIONS
Descriptors DEC
ALKALINE EARTH METALS; DISTRIBUTION; ELEMENTS; MATHEMATICS; MEDICINE; METALS; RADIATION DOSE DISTRIBUTIONS; RADIATION SOURCES; THERAPY