Published September 1975 | Version v1
Journal article

Three-gap spark discharger for wire spark chamber power supply

  • 1. Joint Inst. for Nuclear Research, Dubna (USSR)

Description

A three-gap air spark-discharge device was investigated. The device was investigated. The device is efficient over a wide range of supply voltages; it has an actuation delay anti t = 30 to 60 nsec, depending on the supply voltage; the scatter of the delay is Δ = 7-15 nsec; the duration of the leading edge of the output pulse is approximately 10 nsec. The spark-discharge device is reliable in operation, has a long service life, and is simple to fabricate

Additional details

Additional titles

Original title (Russian)
Трехзазорный искровой разрядник для питания искровых камер

Publishing Information

Journal Title
Prib. Tekh. Ehksp.
Journal Volume
18
Journal Issue
5
Series
Prib. Tekh. Ehksp.
Journal Page Range
105-106

Optional Information

Notes
For English translation see the journal Instrum. Exp. Tech.