Published June 25, 2021
| Version v1
Journal article
Investigation of perfusion defects by Q-SPECT/CT in patients with mild-to-moderate course of COVID-19 and low clinical probability for pulmonary embolism
- 1. Istanbul University-Cerrahpasa, Cerrahpasa Faculty of Medicine. Department of Pulmonary Diseases, Istanbul (Turkey)
Description
Objective
Pulmonary embolism is a severe source of mortality and morbidity in patients with severe and critical coronavirus disease 2019. It is not yet clear whether the tendency to thrombosis is increased in the mild-to-moderate course of COVID-19. Our research aims to show the clinical benefit of Q-SPECT/CT in diagnosing PD in outpatients treated with mild-to-moderate course of COVID-19 and to determine the frequency of perfusion defects in these patients having relatively lower risk.Methods
All patients who underwent Q-SPECT/CT with suspicion of embolism were examined retrospectively. Only patients with low clinical probability and mild-to-moderate course of COVID-19 for PE were included in the study. The patients were evaluated comparatively as those with and without perfusion defects. Patients were divided into laboratory suspicion, clinical suspicion, or clinical and laboratory suspicion.Results
In outpatients with mild-to-moderate COVID-19 with low clinical probability for PE, PD without CT abnormality was detected with a rate of 36.6% with Q-SPECT/CT performed for complaints of high D-dimer and/or dyspnea. None of the patients had PD at more proximal level than the segment level. PD with no concomitant CT abnormality was observed with a rate of 56.5% in patients with both clinical and laboratory suspicion. For D-dimer = 0.5 mg/dL cut-off sensitivity is 85%, for D-dimer = 1.5 mg/dL cut-off specificity 81%.Conclusion
Thrombosis tendency is also present in outpatients with mild-to-moderate COVID-19, and these patients should also be offered anticoagulant prophylaxis during the COVID-19 period. (author)Additional details
Identifiers
Publishing Information
- Journal Title
- Annals of Nuclear Medicine
- Journal Volume
- 35
- Journal Issue
- 10
- Journal Page Range
- p. 1117-1125
- ISSN
- 0914-7187
- CODEN
- ANMEEX
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 54066265
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- CAT SCANNING; CORONAVIRUSES; EMBOLI; IMAGES; LUNGS; PATIENTS; SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY
- Descriptors DEC
- BODY; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DISEASES; EMISSION COMPUTED TOMOGRAPHY; INFECTIOUS DISEASES; MICROORGANISMS; ORGANS; PARASITES; RESPIRATORY SYSTEM; TOMOGRAPHY; VIRAL DISEASES; VIRUSES; ZOONOTIC DISEASES
Optional Information
- Copyright
- Copyright (c) 2021 © The Japanese Society of Nuclear Medicine 2021