Effect of electric field in the characterization of pultruded GFRP boron-free composite insulator for the extra high voltage by the ionizing radiation
Creators
- 1. Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil)
- 2. CHESF, Recife, PE (Brazil)
- 3. Universidade Federal de Campina Grande (UFCG), PB (Brazil)
- 4. Sistema de Transmissao do Nordeste S.A., Recife, PE (Brazil)
Description
Full text: The pultruded boron-free glass fiber reinforced polymer (GFRP) composite has been widely used material for the electrical insulators in the high, extra and ultra high voltage overhead lines worldwide. In terms of design, the composite insulator has a highly complex geometry and large size. Aging of materials begin as soon as the insulators start their operation due to the strong electric field, mechanical load due to the weight of conductor cables, environment, corona discharge, generation of acids, and as a result, GFRP can fail mechanically by the stress corrosion crack (SCC) and electrical breakdown known as flashover. In order to mitigate the mechanical and electrical failures, the insulators in the field are frequently monitored by visual inspection, infrared thermography, UV detection, variation of measurement of distribution of electric field variation. However, new technologies for characterization and inspection of the composite insulator in the field are required for reliable operation. Imaging characterization using ionizing radiation (X-ray or g-ray) is an interesting technique, however, it can reduce drastically breakdown voltage due to the Townsend discharge, which free electrons are accelerated by an electric field, collide with gas molecules of air, and free additional electrons resulting in an avalanche multiplication that allows an electrical conduction through the air. In this study, in order to evaluate the potential application of ionization radiation for characterization of composite insulator under electric field, testing were conducted in high voltage laboratory by applying voltages up to 640 kV and varying radiation area of the composite insulator. As a result, even though there was an occurrence of flame on Imaging Plate (IP) detector case when it was located near the phase, corona discharge, but no breakdown discharge (flashover) occurred and high quality imaging of radiography could be obtained when X-ray source was employed. (author)
Availability note (English)
Available in abstract form only; full text entered in this recordAdditional details
Publishing Information
- Imprint Pagination
- 2 p.
Conference
- Title
- 15. Brazilian MRS meeting
- Dates
- 25-29 Sep 2016
- Place
- Campinas, SP (Brazil)
INIS
- Country of Publication
- Brazil
- Country of Input or Organization
- Brazil
- INIS RN
- 49042525
- Subject category
- S36: MATERIALS SCIENCE;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- COMPOSITE MATERIALS; ELECTRIC FIELDS; ELECTRIC POTENTIAL; ELECTRICAL INSULATORS; FLAMES; IMAGES; IONIZING RADIATIONS
- Descriptors DEC
- ELECTRICAL EQUIPMENT; EQUIPMENT; MATERIALS; RADIATIONS