Published 1987 | Version v1
Book

Evaluations of degraded large snubbers for steam generator supports

  • 1. Harstead Engineering Associates, Inc., Old Tappan, NJ (USA)

Description

The rupture of a main steam line is considered to be a Service Level D Condition, so that Appendix F of ASME Section III applies. Under the rules of Appendix F, yielding is permissable provided structural capacity exists to resist applied loads. For both Units No. 1 and 2, the results of the analysis indicate that even with the snubbers in the degraded conditions Appendix F is satisfied. (orig.HP)

Additional details

Publishing Information

Publisher
Balkema.
Imprint Place
Rotterdam (Netherlands)
ISBN
90-6191-772-7
Imprint Title
Transactions of the 9th international conference on structural mechanics in reactor technology. Vol. K2
Imprint Pagination
669 p.
Journal Page Range
p. 1007-1013.

Conference

Title
9. biennial international conference on structural mechanics in reactor technology (SMIRT-9).
Dates
17-21 Aug 1987.
Place
Lausanne (Switzerland).

INIS

Country of Publication
Netherlands
Country of Input or Organization
Netherlands
INIS RN
19045893
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
DAMPING; DYNAMIC LOADS; FEEDWATER; REACTOR COMPONENTS; RESTRAINTS; RUPTURES; STEAM GENERATORS; STEAM LINES; SUPPORTS
Descriptors DEC
BOILERS; FAILURES; HYDROGEN COMPOUNDS; MECHANICAL STRUCTURES; OXYGEN COMPOUNDS; PIPELINES; POLAR SOLVENTS; SOLVENTS; VAPOR GENERATORS; WATER