Published October 2008 | Version v1
Journal article

Measurement of the time dependent neutron energy spectrum in the 'DENA' plasma focus device

  • 1. Department of Physics, Imam Husein University, PO Box 16575-347, Tehran (Iran, Islamic Republic of)
  • 2. Nuclear Science and Technology Research Institute (NSTRI), Nuclear Science Research School, A.E.O.I., PO Box 14155-1339, Tehran (Iran, Islamic Republic of)
  • 3. Physics Department, Qom University, PO Box 37165, Qom (Iran, Islamic Republic of)

Description

An extended time of flight method is used to determine the time dependent neutron energy spectrum in the Filippove type 'Dena' plasma focus (90 kJ, 25 kV, 288 μF), filled with deuterium gas. An array of 5 detectors containing NE-102 plastic scintillators+photomultipliers is used. The number and position of the detectors are determined by a Monte Carlo program and the MCNP code. This paper briefly describes the simulation method and presents the experimental measurements and their results. The mechanisms of neutron production (thermonuclear and non-thermonuclear) and their time variations are discussed

Availability note (English)

Available from http://dx.doi.org/10.1088/0741-3335/50/10/105003

Additional details

Identifiers

DOI
10.1088/0741-3335/50/10/105003;
PII
S0741-3335(08)79688-X;

Publishing Information

Journal Title
Plasma Physics and Controlled Fusion
Journal Volume
50
Journal Issue
10
Journal Page Range
[7 p.]
ISSN
0741-3335
CODEN
PPCFET