Quantification and distribution of trace elements in fusion bead and pressed pellet specimens using a table top micro-X-ray fluorescence spectrometer
- 1. Homi Bhabha National Institute, Anushaktinagar, Mumbai 400094 (India)
- 2. Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400085 (India)
Description
Highlights: • Assessment of analytical parameters of fusion bead and pressed pelletization methods. • Distribution of trace elements in these specimens was studied using Micro XRF. • Fusion bead specimen has better homogeneity at lower elemental conc. (• Homogeneity increases with elemental concentration in both types of sample specimens. • Trace elemental analysis in real soil sample has been done using fused bead method. Pressed pelletization and fusion bead methods are two very important sample preparation techniques for X-Ray Fluorescence (XRF) analysis. Hence, along with the assessment of these two techniques with respect to its analytical capabilities, it is also very important to study the elemental homogeneity in the prepared specimens. The distribution of trace elements in the specimen prepared using pressed pelletization and fusion bead method were studied using a recently installed table top Micro-XRF (μ-XRF) spectrometer. The spectrometer is equipped with focussing polycapillary lens to obtain the X-ray spot size of 51.3 μm × 33.5 μm. An area of 4 mm × 4 mm was scanned using μ-XRF and the data obtained were used for the elemental mapping of the trace elements in those sample specimens. It was observed that the distribution of trace elements in the specimens depend on their concentration. The elements were distributed more homogeneously in bead than in pellet specimens and the homogeneity increases with the elemental concentration in both the specimens. The μ-XRF determined elemental concentrations of the trace elements in fused bead and pressed pellet specimens were in good agreement with the expected values. However for lower elemental concentration, it was observed that fused bead specimen technique is better. The fused bead technique was utilised to determine trace elemental concentration in a real soil sample.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.sab.2020.106063Additional details
Identifiers
- DOI
- 10.1016/j.sab.2020.106063;
- PII
- S0584854720305024;
Publishing Information
- Journal Title
- Spectrochimica Acta. Part B, Atomic Spectroscopy
- Journal Volume
- 177
- Journal Page Range
- vp.
- ISSN
- 0584-8547
- CODEN
- SAASBH
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 54015808
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S36: MATERIALS SCIENCE;
- Descriptors DEI
- FLUORESCENCE; LENSES; SAMPLE PREPARATION; SOILS; TRACE AMOUNTS; X RADIATION; X-RAY FLUORESCENCE ANALYSIS
- Descriptors DEC
- CHEMICAL ANALYSIS; ELECTROMAGNETIC RADIATION; EMISSION; IONIZING RADIATIONS; LUMINESCENCE; NONDESTRUCTIVE ANALYSIS; PHOTON EMISSION; RADIATIONS; X-RAY EMISSION ANALYSIS
Optional Information
- Copyright
- Copyright (c) 2020 Elsevier B.V. All rights reserved.