Published 1980
| Version v1
Book
Application of an electrochemical cell to hydrogen determination in cover gas and to leak detection in sodium-water steam generators
Creators
- 1. Cent Inst for Nucl Res, Rossendorf, E Ger
Description
Results are presented on testing the measuring device Oxylyt. The hydrogen detector works on the basis of a solid electrolyte cell with coulometric titration of hydrogen in the gas stream. 2 refs
Additional details
Publishing Information
- Publisher
- American Nuclear Society.
- Imprint Place
- Washington, DC
- Imprint Title
- International conference on liquid metal technology in energy production proceedings, 2nd, 1980
- Journal Page Range
- p. 15.16-15.20.
Conference
- Title
- 2. international conference of liquid metal technology for energy systems.
- Dates
- 20 - 24 Apr 1980.
- Place
- Richland, WA (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 14729019
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BOR-60 REACTOR; ELECTROLYTIC CELLS; HYDROGEN METERS; REACTOR COOLING SYSTEMS; SODIUM COOLED REACTORS; STEAM GENERATORS
- Descriptors DEC
- BOILERS; BREEDER REACTORS; COOLING SYSTEMS; ENRICHED URANIUM REACTORS; EPITHERMAL REACTORS; EXPERIMENTAL REACTORS; FAST REACTORS; FBR TYPE REACTORS; LIQUID METAL COOLED REACTORS; MEASURING INSTRUMENTS; POWER REACTORS; REACTOR COMPONENTS; REACTORS; RESEARCH AND TEST REACTORS; VAPOR GENERATORS