Published 1987 | Version v1
Book

Beam injection and extraction system of RIKEN Ring Cyclotron

  • 1. Institute of Physical and Chemical Research, Wako, Saitama (Japan)

Description

From September to December 1985, we carried out comprehensive magnetic field measurements, installing the beam injection and extraction elements at each due position. The magnetic field maps inside the elements as well as those in the sector magnets were measured. The magetic field distributions inside the elements were obtained nearly as expected. On the basis of these data, small modifications were made for some of the elements to improve the distributions. The magnetic field perturbations in the sector magnets could be corrected by the trim coils. At present, October 1986, the whole systems of the RIKEN Ring Cyclotron have been completely assempled and are on standby for commissioning. Layout of the beam injection and extraction system and functions of its each element are described together with some of the measured data. (author)

Additional details

Publishing Information

Publisher
IONICS Publishing Co.
Imprint Place
Tokyo (Japan)
Imprint Title
Eleventh international conference on cyclotrons and their applications
Imprint Pagination
921 p.
Journal Page Range
p. 470-472.

Conference

Title
11. international conference on cyclotrons and their applications.
Dates
13-17 Oct 1986.
Place
Tokyo (Japan).

INIS

Country of Publication
Japan
Country of Input or Organization
Japan
INIS RN
19063640
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BEAM BENDING MAGNETS; BEAM EXTRACTION; BEAM INJECTION; IPCR CYCLOTRON; MAGNETIC FIELDS; PERFORMANCE; SPECIFICATIONS
Descriptors DEC
ACCELERATORS; CYCLIC ACCELERATORS; CYCLOTRONS; EQUIPMENT; HEAVY ION ACCELERATORS; ISOCHRONOUS CYCLOTRONS; MAGNETS