Urinary excretion measurements after accidental inhalation of 99mTc and 99Mo

  • 1. Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain)

Description

The urinary excretion rate of 99Mo and 99Tcm following an accidental occupational exposure has been measured for 1.3-10 days post-exposure. Estimations of intakes and doses based on these results are presented. (author)