TU-A-9A-09: Proton Beam X-Ray Fluorescence CT
Creators
- 1. Stanford University, Stanford, CA (United States)
Description
Purpose: To evaluate x-ray fluorescence computed tomography induced with proton beams (pXFCT) for imaging of gold contrast agent. Methods: Proton-induced x-ray fluorescence was studied by means of Monte Carlo (MC) simulations using TOPAS, a MC code based on GEANT4. First, proton-induced K-shell and L-shell fluorescence was studied as a function of proton beam energy and 1) depth in water and 2) size of contrast object. Second, pXFCT images of a 2-cm diameter cylindrical phantom with four 5- mm diameter contrast vials and of a 20-cm diameter phantom with 1-cm diameter vials were simulated. Contrast vials were filled with water and water solutions with 1-5% gold per weight. Proton beam energies were varied from 70-250MeV. pXFCT sinograms were generated based on the net number of gold K-shell or L-shell x-rays determined by interpolations from the neighboring 0.5keV energy bins of spectra collected with an idealized 4π detector. pXFCT images were reconstructed with filtered-back projection, and no attenuation correction was applied. Results: Proton induced x-ray fluorescence spectra showed very low background compared to x-ray induced fluorescence. Proton induced L-shell fluorescence had a higher cross-section compared to K-shell fluorescence. Excitation of L-shell fluorescence was most efficient for low-energy protons, i.e. at the Bragg peak. K-shell fluorescence increased with increasing proton beam energy and object size. The 2% and 5% gold contrast vials were accurately reconstructed in K-shell pXFCT images of both the 2-cm and 20-cm diameter phantoms. Small phantom L-shell pXFCT image required attenuation correction and had a higher sensitivity for 70MeV protons compared to 250MeV protons. With attenuation correction, L-shell pXFCT might be a feasible option for imaging of small size (∼2cm) objects. Imaging doses for all simulations were 5-30cGy. Conclusion: Proton induced x-ray fluorescence CT promises to be an alternative quantitative imaging technique to the commonly considered XFCT imaging with x-ray beams
Additional details
Identifiers
- DOI
- 10.1118/1.4889244;
Publishing Information
- Journal Title
- Medical Physics
- Journal Volume
- 41
- Journal Issue
- 6
- Journal Page Range
- p. 449
- ISSN
- 0094-2405
- CODEN
- MPHYA6
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 46115513
- Subject category
- S60: APPLIED LIFE SCIENCES;
- Descriptors DEI
- BRAGG CURVE; COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; FLUORESCENCE; FLUORESCENCE SPECTROSCOPY; GOLD; K SHELL; L SHELL; MONTE CARLO METHOD; PHANTOMS; PROTON BEAMS; X RADIATION
- Descriptors DEC
- BEAMS; CALCULATION METHODS; DIAGNOSTIC TECHNIQUES; DIAGRAMS; ELECTROMAGNETIC RADIATION; ELECTRONIC STRUCTURE; ELEMENTS; EMISSION; EMISSION SPECTROSCOPY; EVALUATION; INFORMATION; IONIZING RADIATIONS; LUMINESCENCE; METALS; MOCKUP; NUCLEON BEAMS; PARTICLE BEAMS; PHOTON EMISSION; RADIATIONS; SPECTROSCOPY; STRUCTURAL MODELS; TOMOGRAPHY; TRANSITION ELEMENTS
Optional Information
- Notes
- (c) 2014 American Association of Physicists in Medicine