This report presents the results of a cost/benefit analysis for the addition of a feed-and-bleed capability to the San Onofre Nuclear Generating Station, Unit 2, (SONGS 2). Two cases of feed-and-bleed capability were investigated: 1) adding power-operated relief valves (PORVs) to the pressurizer for depressurization and using the present high-pressure safety-injection (HPSI) system for reactor-coolant-system (RCS) inventory make-up and 2) adding an independent single-train feed-and-bleed system. For the first case, it is estimated that the core-melt frequency would be incrementally reduced by 4.0E-6 per year, a factor of 1.3, at a cost of $2.5 M to $4.3 M depending on when the equipment is installed. For the second case, it is estimated that the core-melt frequency would be incrementally reduced by 1.2E-5 per year, a factor of 3, at a cost of $7.0 M to $10.3 M

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A08/MF A01; 1 - GPO as DE84001183.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
164 p.
Report number
NUREG/CR--3421

Optional Information

Secondary number(s)
SAND--83-1629.