Published January 1968 | Version v1
Journal article

Measurement of material buckling of U-H2O assembly

  • 1. Japan Atomic Energy Research Institute, Tokai, Ibaraki (Japan)

Description

A method of determining the material buckling of a cylindrical subcritical assembly is described. The new technique is an improved 'flux shape' method that is based upon the complete orthogonality of the Bessel function. To obtain sufficient accuracy, a scintillation detector with a very thin scintillator has been used. The result indicates that the present method yields a value of buckling free from higher harmonics and end effects, with a standard deviation of 3.0% under centric point source condition. The buckling obtained is - (7.08±0.23) x 10-4 cm-2. This lies between the values measured by conventional 'flux shape' and 'variable loading' methods, which are amenable to unwanted effects. (author)

Availability note (English)

Available from DOI: https://doi.org/10.1080/18811248.1968.9732388

Additional details

Publishing Information

Journal Title
Journal of Nuclear Science and Technology (Tokyo) (Online)
Journal Volume
5
Journal Issue
1
Journal Page Range
p. 1-6
ISSN
1881-1248

Optional Information

Notes
7 refs., 4 figs., 1 tab.