AGR boilers are likely to require post service chemical cleaning to remove accumulated oxides at intervals of 15 - 35 kh. The need to clean will be based on an assessment of such factors as the development of flow imbalances through parallel tubes induced by the formation of rough oxide surfaces, an increasing risk of localised corrosion as the growth of porous oxides proceeds and the risk of tube blockage caused by the exfoliation of steam-grown oxides. The study has shown what heterogeneous multilayer oxides possessing a range of physical and chemical properties form on the alloy steels. They include porous and compact magnetites, chromium spinels and sesquioxide. Ammoniated citric acid has been shown to remove deposited and water-grown magnetites from the carbon and alloy steels but will not necessarily remove the substituted spinels grown on the alloy steels or the potentially spalling steam-grown magnetite on the A1SI 316 superheater. Citric acid supplemented with the reducing agent glyoxal completely removes all oxides from the boiler except the protective inner spinel formed on the 316. Removal of the spinels and compact magnetites occurs more by undercutting and physical detachment than by the dissolution. (author)

Additional details

Publishing Information

Publisher
Thomas Telford for BNES.
Imprint Place
London
ISBN
0 7277 0053 7
Imprint Title
Water chemistry of nuclear reactor systems. Proceedings of an international conference organized by the British Nuclear Energy Society, Bournemouth, 24-27 October 1977
Journal Page Range
p. 407-415.

Conference

Title
International conference on water chemistry of nuclear reactor systems.
Dates
24 - 27 Oct 1977.
Place
Bournemouth, UK.