Treatment planning comparison between conformal radiotherapy and helical tomotherapy in the case of locally advanced-stage NSCLC
Creators
- 1. Medical Physics, University of Milano Bicocca, Milano (Italy)
- 2. Radiation Oncology, University of Milano Bicocca, Milano (Italy)
- 3. INB-CNR, University of Milano Bicocca, Milano (Italy)
Description
Background and Purpose: To investigate the impact of Helical Tomotherapy (HT) upon the dose distribution when compared to our routinely delivered 3D conformal radiotherapy (CRT) in the case of patients affected by stage III non-small-cell lung cancer (NSCLC). Material and methods: Thirteen stage III inoperable NSCLC patients were scheduled to receive 61.2-70.2 Gy, 1.8 Gy/fraction. Two treatment techniques (HT and CRT) were considered, and in the case of CRT the dose calculation was performed using both the pencil beam (PB) and Anisotropic Analytical Algorithm (AAA) available on the Varian Eclipse planning system. Dose volume constraints for PTV coverage and OAR sparing were assessed for the HT inverse planning with the highest priority upon PTV coverage and spinal cord sparing. The three plans were compared in terms of dose-volume histograms (DVHs) and normal tissue complication probability (NTCP). A statistical analysis was performed using non-parametric Wilcoxon matched pairs tests. Results: In CRT the use of a less accurate algorithm (PB) decreased the monitor unit number by 2.4%. HT significantly improved dose homogeneity within PTV compared with CRTAAA. For lung parenchyma V20-V40 were lower with HT, corresponding to a decrease of 7% in the risk of radiation pneumonitis. The volume of the heart and esophagus irradiated to >45-60 Gy were reduced using HT plans. For eight PTs with an esophagus-PTV overlap >5%, HT significantly reduced both late and acute esophageal complication probability. Conclusions: Our findings obtained in stage III NSCLC patients underline that HT guarantees an important sparing of lungs and esophagus, thus HT has the potential to improve therapeutic ratio, when compared with CRT, by means of dose escalation and/or combined treatment strategy. In CRT of locally advanced lung cancers, the use of a more advanced algorithm would give significantly better modeling of target dose and coverage
Availability note (English)
Available from http://dx.doi.org/10.1016/j.radonc.2008.06.006Additional details
Identifiers
- DOI
- 10.1016/j.radonc.2008.06.006;
- PII
- S0167-8140(08)00333-2;
Publishing Information
- Journal Title
- Radiotherapy and Oncology
- Journal Volume
- 88
- Journal Issue
- 3
- Journal Page Range
- p. 310-318
- ISSN
- 0167-8140
- CODEN
- RAONDT
INIS
- Country of Publication
- Ireland
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 40005315
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ALGORITHMS; ANISOTROPY; CARCINOMAS; COMPUTERIZED TOMOGRAPHY; CT-GUIDED RADIOTHERAPY; ESOPHAGUS; HEART; IRRADIATION; LUNGS; RADIATION DOSE DISTRIBUTIONS; RADIATION DOSES; SPINAL CORD
- Descriptors DEC
- BODY; CARDIOVASCULAR SYSTEM; CENTRAL NERVOUS SYSTEM; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; DISEASES; DOSES; MATHEMATICAL LOGIC; MEDICINE; NEOPLASMS; NERVOUS SYSTEM; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; RADIOTHERAPY; RESPIRATORY SYSTEM; THERAPY; TOMOGRAPHY
Optional Information
- Copyright
- Copyright (c) 2008 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.