Establishment of the neutron dose calibration fields with a 252Cf source based on Monte-Carlo methods

  • 1. Nuclear Research Institute, Dalat (Viet Nam)
  • 2. Vietnam Atomic Energy Institute, Hanoi (Viet Nam)

Description

This paper presents calculation results based on Monte-Carlo methods to select the appropriate a neutron moderated material in order to design 4 relevant configurations of a neutron dose calibration system with a 252Cf source. These calibration configurations provide 6 neutron spectra with the various average energies: 1.04 MeV, 1.38 MeV, 1.69 MeV, 2.05 MeV, 2.46 MeV and 2.93 MeV satisfied for the calibration of the neutron survey meters and personal dosimeters. (author)

Part of:
The 11th National Conference on Nuclear Science and Technology. Agenda and Abstracts

Additional details

Additional titles

Original title (Vietnamese)
Thiet lap truong chuan lieu notron voi nguon phong xa 252Cf bang phuong phap Monte-Carlo

Publishing Information

Imprint Title
The 11th National Conference on Nuclear Science and Technology. Agenda and Abstracts
Imprint Pagination
215 p.
Journal Page Range
7 p.
Report number
INIS-VN--002

Conference

Title
Radiation Measurement, Radiation Safety and Environmental Monitoring
Original Conference Title
Hoi nghi Khoa hoc va Cong nghe Hat nhan Toan quoc lan thu 11
Acronym
11. National Conference on Nuclear Science and Technology. Section C
Dates
5-7 Aug 2015
Place
Da Nang City (Viet Nam)

Optional Information

Notes
15 refs, 3 figs, 8 tabs